Showing posts with label WAC. Show all posts
Showing posts with label WAC. Show all posts

06 November 2023

Finding weak fragments for membrane proteins with WAC

Last week we wrote about NMR, one of the most popular fragment-finding methods. This week we turn to a less common technique: weak affinity chromatography, or WAC. As we’ve written previously, WAC involves immobilizing a protein of interest in a chromatography column and flowing a ligand-containing solution through the column. If the ligand interacts with the protein, its elution time will be delayed in proportion to its affinity. In a new (open-access) Molecules paper, Claire Demesmay and collaborators at Universite Claude Bernard Lyon and Ecole Supérieure de Biotechnologie de Strasbourg extend the technique to membrane proteins.
 
Membrane proteins are themselves tricky to study, since removing them from their membranes often denatures them. One trick is to use nanodiscs, which are tiny lipid bilayer islands surrounded by proteins that keep them soluble in water. These scaffolding proteins can also be biotinylated so that the nanondiscs can be attached to streptavidin, which itself can be linked to a surface or matrix. Each nanodisc holds one or at most a few membrane proteins.
 
When we first wrote about WAC in 2011 the technique used standard HPLC columns, which required non-negligible amounts of protein. Here, the technique has been miniaturized to use glass capillaries with volumes of less than 1 microliter, requiring only a few tens of picomoles of protein. The researchers fill the capillaries with a bio-compatible polymer, functionalize it with streptavidin, and then capture biotinylated nanodiscs containing the membrane protein of interest.
 
A long-recognized challenge with WAC is nonspecific binding of the fragments to the column or matrix. Here, the researchers chose a filling (or monolith) that is more hydrophilic (for aficionados, they picked poly(DHPMA-co-MBA)) and found it superior to the previous polymer both with regards to capacity and non-specific binding.
 
Another challenge with WAC is detecting low-affinity binders: because interactions with the protein are weak, the shift in retention time is harder to detect. One solution is to pack more protein in the column, and the researchers develop a clever way of doing this with a “multilayer grafting” approach in which successive injections of streptavidin and nanodiscs more effectively fill the capillary. The combination of a more hydrophilic filling and multilayer grafting increased the column capacity for nanodiscs by three-fold.
 
The researchers tested their approach on the adenosine-A2A receptor (AA2AR), which has frequently been used as a model GPCR. Two previously reported weak ligands, both with affinities around 0.2 mM, could be detected, and competition with an orthosteric binder revealed that they were binding specifically.
 
This is a nice, how-to guide for performing WAC on membrane proteins, and the paper includes detailed equations for calculating affinities from differences in retention times. I look forward to seeing the technique used in de novo screens.

30 December 2018

Review of 2018 reviews

As 2018 recedes into history, we are using this last post of the year to do what we have done since 2012 – review notable events along with reviews we didn’t previously cover.

This was a busy year for meetings, starting in January with a FragNet event in Barcelona, then moving to San Diego in April for the annual CHI FBDD meeting. Boston saw an embarrassment of riches, from the first US-based NovAliX meeting, to a symposium on FBDD at the Fall ACS meeting, followed closely by a number of relevant talks at CHI’s Discovery on Target. Finally, the tenth anniversary of the renowned FBLD meeting returned to San Diego. Look for a schedule of 2019 events later this month.

If meetings were abundant, the same can be said for reviews.

Lead optimization
Writing in J. Med. Chem., Dean Brown and Jonas Boström (AstraZeneca) asked “where do recent small molecule clinical development candidates come from?” For three quarters of the 66 molecules published in J. Med. Chem. in 2016 and 2017 the answer is from known compounds or HTS, though fragments accounted for four examples. Although average molecular weight increased during lead optimization, lipophilicity did not, suggesting the importance of this parameter.

The importance of keeping lipophilicity in check is also emphasized by Robert Young (GlaxoSmithKline) and Paul Leeson (Paul Leeson Consulting) in a massive J. Med. Chem. treatise on lead optimization. Buttressed with dozens of examples, including several from FBLD, they show that the final molecule is usually among the most efficient (in terms of LE and LLE) in a given series, even when metrics were not explicitly used by the project team. Perhaps with pedants like Dr. Saysno in mind, they also emphasize the complexity of drug discovery, and note that “seeking optimum efficiencies and physicochemical properties are guiding principles and not rules.”

Lipophilic ligand efficiency (LLE) is also the focus of a paper in Bioorg. Med. Chem. by James Scott (AstraZeneca) and Michael Waring (Newcastle University). This is based largely on personal experiences and provides lots of helpful tips. Importantly, the researchers note that calculated lipophilicity values can differ dramatically from measured values, and go so far as to say that “this variation is sufficient to render LLEs derived from calculated values meaningless.”

Turning wholly to fragments, Chris Johnson and collaborators (including yours truly) from Astex, Carmot, Vrije Universiteit Amsterdam, and Novartis have published an analysis in J. Med. Chem. of fragment-to-lead success stories from last year. This review, the third in a series, also summarizes all 85 examples published between 2015 and 2017, confirming and expanding some of the trends we mentioned last year.

Targets
Two reviews focus on specific target classes. Bas Lamoree and Rod Hubbard (University of York) cover antibiotics in SLAS Discovery. After a nice, concise review of fragment-finding methods, the researchers discuss a number of case studies, many of which will be familiar to regular readers of this blog, including an early example of whole-cell screening.

David Bailey and collaborators from IOTA and University of Cambridge discuss cyclic nucleotide phosphodiesterases (PDEs) in J. Med. Chem. The researchers provide a good overview of the field, including mining the open database ChEMBL for fragment-sized inhibitors. As they point out, the first inhibitors discovered for these cell-signaling enzymes were fragment-sized, so it is no surprise that FBLD has been fruitful – see here for an example from earlier this year. Interestingly though, although at least six fragment-sized PDE inhibitor drugs have been approved, none of these were actually discovered using FBLD.

PDEs are an example of “ligandable” targets, for which small molecule modulators are readily discovered. In Drug Discovery Today, Sinisa Vukovic and David Huggins (University of Cambridge) discuss ligandability “in terms of the balance between effort and reward.” They use a published database of protein-ligand affinities to develop a metric, LIGexp, for experimental ligandability, and also describe their computational metric, Solvaware, which is based on identifying clusters of water molecules binding weakly to a protein. Comparisons with experimental data and with other predictive metrics, such as FTMap, reveal that while the computational methods are useful, there is still room for improvement.

We have previously written about how target-guided synthesis methods such as dynamic combinatorial chemistry have – despite decades of research – yielded few truly novel, drug-like ligands. Is this because the targets chosen were simply not ligandable? In J. Med. Chem., Anna Hirsch and collaborators at the University of Groningen, the Helmholtz Institute for Pharmaceutical Research, and Saarland University review some (though by no means all) published examples and examine their computationally determined ligandability scores. There seems to be no difference between these targets and a set of traditional drug targets.

Finding fragments
Crystallography continues to be a key tool for FBLD: as we noted in the review of the 2017 literature, 21 of the 30 examples made use of a crystal structure of either the starting fragment or an analog, and only 3 projects didn’t use crystallography at all. That said, FBLD is possible without crystallography, as illustrated through multiple examples in a Cell Chem. Biol. review by Wolfgang Jahnke (Novartis), Ben Davis (Vernalis), and me (Carmot).

In the absence of a crystal structure, NMR is best suited for providing structural information, and this is the subject of a review in Molecules by Barak Akabayov and colleagues at Ben-Gurion University of the Negev. The researchers provide a nice summary of NMR screening methods and success stories within a broader history of FBLD. They also include an extensive list of fragment library providers as well as a discussion of virtual screening.

Speaking of virtual screening, three reviews cover this topic. In Methods Mol. Biol., Durai Sundar and colleagues at Indian Institute of Technology Delhi touch on a number of computational approaches for de novo ligand design, though the lack of structures sometimes makes it challenging to read. A broader, more visually appealing review is published in AAPS Journal by Yuemin Bian and Xiang-Qun Xie at University of Pittsburgh. In addition to an overview and case studies, the researchers also provide a nice table summarizing 15 different computational programs. One of these, SEED, is a main focus of a review in Eur. J. Med. Chem. by Jean-Rémy Marchand and Amedeo Caflisch (University of Zürich). The researchers describe how this docking program can be combined with X-ray crystallography (SEED2XR) to rapidly identify fragments; we highlighted an example with a bromodomain. Their ALTA protocol uses SEED to generate larger, more potent molecules, as we described for the kinase EphB4. The researchers note that together these protocols have led to about 200 protein-ligand crystal structures deposited in the PDB over the past five years.

Rounding out methods, Sten Ohlson and Minh-Dao Duong-Thi (Nanyang Technological University) provide a detailed how-to guide in Methods for performing weak affinity chromatography, and how this can be combined with mass spectrometry (WAC-MS), as we noted last year.

Chemistry
One drawback of some computational approaches for fragment optimization is that they do not consider synthetic accessibility. In Mol. Inform., Philippe Roche, Xavier Morelli, and collaborators at Aix-Marseille University and Institut Paoli-Calmettes focus on hit to lead approaches that do, and provide a handy table summarizing nearly a dozen computational methods. We highlighted one from the authors, DOTS, earlier this year.

DOTS is an example of using DOS, or diversity-oriented synthesis. In Front. Chem., David Spring and colleagues at University of Cambridge review recent applications of DOS for generating new fragments, some of which we recently highlighted. Only a couple examples of successfully screening these new fragments are described, but the authors note that this is likely to increase as virtual library screening continues to advance.

Perhaps the most productive fragment of all time is 7-azaindole, the origin of three fragment-derived clinical compounds. (The moiety appears in both approved FBLD-derived drugs, vemurafenib and venetoclax.) Takayuki Irie and Masaaki Sawa of Carna Biosciences devote their attention to this little bicycle in Chem. Pharm. Bull. The researchers count six clinical kinase inhibitors that contain 7-azaindole (not all from FBLD) as well as more than 100,000 disclosed compounds containing the fragment. More than 90 kinases have been targeted by molecules containing 7-azaindole, and the paper provides a list of 70 PDB structures of 37 different kinases bound to molecules containing the moiety.

Finally, in J. Med. Chem., Brian Raymer and Samit Bhattacharya (Pfizer) survey the universe of “lead-like” drugs. Among the most highly prescribed small molecule drugs, 36% have molecular weights below 300 Da. Only 28 of 174 drugs approved between 2011 and 2017 fall into this category, consistent with the increasing size of newer drugs. The researchers discuss 16 recently approved drugs, and find that 13 have very high ligand efficiencies (at least 0.4 kcal mol-1 per heavy atom). As noted above, optimization often entails adding molecular weight by growing or linking, and the researchers suggest that alternative strategies such as conformational restriction and truncation also be investigated.

And with that, Practical Fragments wishes you a happy new year. Thanks for reading some of our 686 posts over the past decade plus, and please keep the comments coming!

21 October 2015

LO-MS...Coming of Age.

There are many ways to screen for fragments.  One of the really emerging areas uses mass spec detection: WAC, native mass spec, HDX, and ligand-observed MS.  The group that we highlighted back in March has a new paper where they look at the method in terms of accuracy of Kd determination and compare the results to other biophysical methods.  

Their previous work they looked at relative affinity ranking of bound fragments.  In this study, they compared the accuracy of Kd determination in this method to ITC.  First they used a pool of 3 or 4 known CAI inhibitors and a pool of 50 fragments (from their collection).  The conditions were defined:
The hCAI protein was incubated with each inhibitor mixture in the binding buffer with a total volume of 50 mLat room temperature for 40 min. The protein concentration was maintained at 25 mM and the inhibitor concentration increased from 1 mM to 50 mM. The control was prepared by using the binding buffer substitute for hCAI during incubation. The incubation solution was then filtered through a 10 kDa MW cutoff ultrafiltration membrane by centrifugation at 13,000 g for 10 min at 4 C followed by a quickwash with 10mM ammonium acetate (pH 8.0) to remove the unbound compounds.
 Two different methods were used to calculate Kd: 1. saturation curves and 2. measuring the unbound fraction of ligand .  Method 1 was deemed unsuitable for determining Kds for ligands with largely different Kds.  Method 2 did not depend on saturation curve fitting, instead using a calibration curve and did not observe any fragment competition at higher P:L ratios (6:1 or 8:1).  This approach also improved the sensitivity of the assay allowing better detection of lower affinity ligands.  Kds determined using this method matched those determined by ITC.  

To further test the method, they ran a pool of 50 fragments against HCV RNA polymerase NS5B.  This gave, as expected, a complicated chromatographic baseline.  To exclude promiscuous binders, they ran against BSA in parallel.  Eight fragments in the mixed pool showed selective binding to NS5B using unbound fraction analysis vs. 2 from the bound fraction analysis.  7 of 8 fragments were confirmed by SPR (ITC could not be used).  The 1 BFA fragment to be analyzed by SPR showed that it was a very weak binder.  

This sort of work makes me happy.  Methods always need to be pushed and evaluated.  When evaluating methods, if this sort of cross validation hasn't been done, question as to why not? 

30 October 2014

That's Just WAC

We are all about new methods here.  One method I have never been a big fan of is Weak Affinity Chromatography, which has been reviewed here, here, and here.  In this method, a target is immobilized on a column and compounds are flowed through and retarded if they interact. Affinity is determined by retention time, which we all know is never influenced by experimental conditions.  In this paper, the KDs determined by WAC are compared to those by SPR, as well as efficiency and consumption of materials.

As a model system they used alpha-thrombin, either in the active form or the covalently inactivated form.  Figure 1 shows the results for one compound. 
Figure 1.  A. WAC: tspec is difference in retention time for active (solid) and inactive (dashed) protein.  B. Triplicate response generated by subtracting in situ inhibited protein from active protein.  C. Isotherm from SPR. 
SPR required 120 minutes for triplicate data at 10 concentrations; WAC required 175 minutes.  WAC however can require up to 525 minutes for a single compound.  The authors note that Mass Spec detection can speed this up greatly by allowing multiplexing of ligands.  SPR requires more compound, but far less protein (25ug vs. 0.5mg).  As a counterpoint, they claim their thrombin column has a far longer lifetime than the thrombin chip.  In terms of robustness, WAC does not suffer from DMSO interference, while SPR can be mucked with by SPR, resulting in poor isotherm fits.  They noted this in 13 of 27 compounds they studied.  All 27 compounds were able to have isotherms generated by WAC.
 There is a high degree of correlation between the KDs determined by SPR and WAC.  The authors note one major factor is that similar conditions were used for both studies, while in the past this was not true.  In summary, SPR is faster, consumes less protein, and has higher throughput.  WAC uses less sample.  WAC, for future development, can use Mass Spec can give a advantage in terms of being able to multiplex compounds.  I am still not a fan of the method, but I want to give kudos to the authors who continue to develop the method. 

13 November 2013

WAC vs other methods: all roads lead to good fragments

Among the many ways to find fragments, one of the relatively inexpensive newcomers is weak affinity chromatography, or WAC (see also here). The technique works by immobilizing a target protein onto a column and flowing fragments over it; molecules that bind to the target will elute more slowly than those that don’t. WAC has a number of potential benefits, but as with any technique the question is how well it really works. In a paper published a few months ago in Analytical Chemistry, Sten Ohlson at Linnaeus University and collaborators at Vernalis compared WAC with more established methods.

The protein they chose, HSP90, is sort of the fruitfly of FBLD: just about every technique has been tested on it. It’s also an oncology target with which Vernalis has many years of experience. The researchers chose 111 fragments from the Vernalis library and screened these using WAC. They also screened most of the fragments using surface plasmon resonance (SPR), fluorescence polarization (FP), thermal shift, and NMR (using three techniques: STD, waterLOGSY, and relaxation filtered spectra; only fragments that confirmed in all three NMR assays were considered hits).

The top 27 hits from WAC were also investigated with isothermal titration calorimetry (ITC), and 32 hits were soaked into crystals for X-ray crystallography.

The results were quite encouraging, with good agreement between the different methods:


NMR performed the best, though this could be due in part to the fact that three separate NMR techniques were used. Thermal shift performed the worst, with both false positives as well as false negatives, but even here the agreement was always greater than 50%. It is also important to note that assay conditions varied from technique to technique (for example, the pH ranged from 6.5 to 7.5), which could account for many of the discrepancies.

These results are in sharp contrast to some other comparisons of fragment finding methods (such as here and here), which showed little or no correlation between hits. Why the difference? One possibility is that the folks at Vernalis have worked out all the kinks in their assays and are very adept at separating the true hits from the chaff. Of course, it probably doesn’t hurt that they were working with a well-behaved and extensively characterized target.

The main focus of the paper is WAC, which performed admirably. Compounds could be screened in pools of up to 16 fragments when mass-spectrometry was used as a detection method, and less than 2 milligrams of HSP90 was used to prepare all three of the WAC columns made. One worry with immobilizing your protein is long term stability, but the columns seemed to be stable for at least 6 months through multiple runs.

Of course, no technique is perfect, and one area where WAC gets whacked is in determining dissociation constants. The correlation between KD values measured by SPR and ITC was excellent (R2 = 0.91) but much worse for WAC versus ITC (R2 = 0.38) and nonexistent for WAC versus SPR (R2 = 0.016), though some of this could possibly be explained by differences in buffer conditions.

Overall it looks like WAC is a great way to find fragments, though you may want to use other methods to actually quantify binding. This paper provides a detailed guide for using WAC, as well as good descriptions of other fragment-finding methods.

01 November 2012

WACing GAK and thrombin (faster)



Last year we highlighted a fragment-finding technique called weak affinity chromatography, or WAC. Those of you who were at FBLD 2012 saw some nice updates on the approach, but if you missed the meeting you can read two new papers. In the first of these (in Anal. Bioanal. Chem.), Elinor Meiby and Sten Ohlson at Linnaeus University, in collaboration with researchers at Oxford University, describe the use of WAC against a kinase.

Recall that WAC works by immobilizing a protein onto an HPLC column and then flowing ligands through the column; ligands that bind to the protein will have longer retention times compared to their retention times in a column without bound protein. Small amounts of fragments can be injected (2 picomoles in this case), and the fragments are at low concentration, minimizing potential artifacts.

Here the researchers were interested in cyclin G-associated kinase (GAK), a potential target for Parkinson’s disease. They used less than 1 mg of protein to prepare their column and used adenosine as a positive control to show that at least 22% of the protein was still active. They then performed a virtual screen of 3200 fragments (from TimTec), looking for molecules that would bind to the ATP site of five different proteins; the 170 highest-scoring fragments were then tested by WAC in mixtures of 13 compounds. Despite the use of mixtures, run times were long (140 minutes per injection), so this was not a high-throughput approach, although more compounds could potentially be injected simultaneously (see below).

Mass-spectrometry was used as a detection method to identify fragments. The change in retention time between the protein column and reference column is related to the dissociation constant, and the researchers found that 78 of the fragments had an estimated Kd of better than 0.2 mM, a fairly high hit rate. (30 of the 170 molecules could not be detected on both the GAK and reference column, so over half of the assessed molecules tested positive.) However, it is possible that some of the fragments bind to but don’t inhibit the protein. In fact, 23 fragments eluted more slowly from the reference column than from the protein-containing column, illustrating that non-specific effects are certainly possible (see also below). That said, many of the best fragments are structurally similar to known kinase inhibitors.

One of the coolest features of WAC is that a couple of the fragments were racemic, and these gave double peaks on the GAK column but only single peaks on the reference column, suggesting that one of the two enantiomers binds more tightly than the other.

As noted earlier, this campaign was not high-throughput, and in the second paper (in J. Biomol. Screen) Minh-Dao Duong-Thi, Sten Ohlson, and collaborators at Linnaeus and AstraZeneca sought to speed things up. They took 590 fragments from their larger collection and pooled them into 11 groups of 35-65 members in DMSO, with final concentrations of each fragment as low as 0.023 mM. Fragments likely to be positively charged were pooled together, and negatively charged fragments were pooled separately to facilitate mass spectrometry analysis. Also, fragments in each pool were chosen to have unique molecular weights to facilitate unambiguous identification.

These researchers looked for hits against thrombin, a protein they had previously used in developing WAC. The mixtures were screened in 20-minute runs, so all 590 fragments were screened in under 4 hours. 60 fragments were not observed in the mixtures, but 36 of these could be detected when injected singly under more optimized conditions.

The 30 best hits were then confirmed by injecting them individually. To assess whether they bind to the active site of thrombin, the enzyme was inactivated with an irreversible inhibitor, and the fragments retested. Remarkably, only a single fragment showed a significant reduction in binding to the inactivated protein, suggesting that the other fragments were either promiscuous or bound to regions outside the active site. The selective fragment contains an amidine moiety, a known thrombin-binding motif.

This paper demonstrates that WAC can be done in a fairly high-throughput manner. Although the number of non-selective binders does raise concerns, WAC could still be a valuable primary screening method, particularly given that it can be done using standard laboratory equipment.

18 March 2011

Weak affinity chromatography (WAC)

There are many ways to find fragments: NMR and X-ray crystallography are old favorites, but SPR is quickly catching on. There are also more specialized approaches, such as ITC, MS, TINS, and biochemical screening. Now another 3-letter abbreviation has joined the list: a paper published online by Sten Ohlson and colleagues at Linnaeus University in Sweden in Analytical Biochemistry describes weak affinity chromatography, or WAC.

The principle is remarkably simple. First, a protein of interest is covalently immobilized onto a chromatography column packed with modified silica gel. This can be done on a standard high-performance liquid chromatograph (HPLC). Then each fragment to be tested is injected in buffer; those that have affinity for the immobilized protein will stay on the column longer than they would if they lacked affinity. The fragments can be detected with either UV spectrometry or mass spectrometry.

To demonstrate the technique, the researchers used two model enzymes, thrombin and trypsin, and a couple dozen fragments ranging in mass from 93 to 307 Da. Most of these fragments contained an amidine, a moiety known to bind to both proteins. Columns without any immobilized protein served as controls. Of course, fragments may associate non-specifically with proteins, so the researchers also treated protein-containing columns with irreversible or potent reversible inhibitors; a fragment that comes out later from a column containing an active protein than from a column containing an inactive protein is presumably binding specifically to the active site.

Remarkably, the technique appears to work: most of the amidine-containing fragments were retarded in columns containing active protein compared to columns containing inhibited protein. Moreover, the relative affinity ranking correlated with the inhibitory activity of fragments in enzymatic assays. Some of the fragments were quite weak, with calculated dissociation constants around 1 mM.

The researchers also demonstrated that they could screen a mixture of 11 fragments, using mass-spectrometry to follow each fragment, and that the change in retention time was comparable to that observed when running each fragment individually. In this case it was important to use low fragment concentrations so as to avoid saturating the protein active sites.

As with any technique, there are bound to be limitations. The immobilized protein needs to be stable for an extended time; in the current case there was some degradation in performance, albeit over the course of months and more than 200 injections. A more serious constraint is the need for a proper reference. Inactivating an enzyme provides an ideal solution, but one that won’t be so easily generalized to all targets.

In some ways WAC could be seen as a low-price cousin of TINS: both methods rely on an immobilized protein, but while TINS uses a custom modified NMR spectrometer, WAC can get by with a much less pricey HPLC (though a mass-spectrometer seems nearly indispensible). It will be fun to see how WAC develops, and in particular whether it can be used to discover novel fragments against more challenging targets.